Honeywell Security Intrusion and Communications, ADEMCO, AlarmNet, IntelliSense, Apex, FBII, electronic security systems, burglary alarms and fire alarms for. Installation manual for the Honeywell wireless three-zone sensor. For help installing your , call The Honeywell is a wireless three zone sensor. Unlike other Honeywell wireless window and door sensors, the does not have an internal reed switch.

Author: Mekinos Daizil
Country: Mexico
Language: English (Spanish)
Genre: Business
Published (Last): 9 April 2008
Pages: 337
PDF File Size: 16.43 Mb
ePub File Size: 2.59 Mb
ISBN: 521-2-14465-834-3
Downloads: 35268
Price: Free* [*Free Regsitration Required]
Uploader: Dougar

Attach the case back to the mounting plate by sliding the keyhole slots in the case back down. Install the mounting plate, with its case holding posts pointing up in this examplein the.

When a satisfactory location is found, remove the battery and proceed with installation.

Honeywell ADEMCO 3 Point Wireless Transmiter | eBay

If a contact loop is not to be used, no connection is needed across its terminals. If concealed wiring is to be used, feed it through the slot in the case back but do not connect. Disengage the supplied mounting plate from the unit by inserting the blade of a small screwdriver into the locking tab release window see Diagram 2 and pressing it against the case locking tab see Diagram 1 while sliding the plate downward along the case back.

Replace battery only with: For UL installations, no contact in any of the loops may be more than 3 feet from the transmitter. Comments wdemco this Manuals Your Name. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. Except in the case of the position 4 ON setting, the Auxiliary loops are not affected by.

Page of 2 Go.

Disengage the supplied mounting plate from the unit by inserting the blade of a small. Don’t show me this message again. The locking adekco will click as the case back locks in place. Don’t have an account?

  ALCOR AU6982 PDF

The installer should assume the responsibility of developing and offering a regular maintenance.

Honeywell ADEMCO 5817 Installation And Setup Manual: Wiring Connections; Specifications

Each loop transmits a unique ID code to a wireless system receiver connected to the system control panel. Complain wrong Brand wrong Model non readable.

Addmco must be included for a specific. Observe correct polarity and insert the battery provided into the battery holder see. Surface wiring should enter via the thin “breakout” area provided in.

Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product s which is proved ademvo in compliance with Seller’s specifications or proves defective in materials or workmanship under normal use and service. The Primary Loop has several DIP switch selectable options that determine its connection requirements, response, and transmission characteristics see DIP switch setting table on next page.

The unit may, however, be installed in any direction, as long as the relationship of ademoc unit to its mounting plate is maintained. With the battery still not inserted, connect the loop wiring to the unit’s terminals see Diagram 2. Enter text from picture: This warranty replaces any previous warranties and is the only warranty made by Seller on this product s.

Honeywell ADEMCO User Manual | 2 pages

Mounting For proper daemco of the unit in relation to its wall mounting plate and the loop wiring, read all of this section before installing the unit. The two Auxiliary Loops are closed-circuit, with a nominal response time of mSec. Do not recharge, disassemble, heat above. It is not necessary to program the transmitter IDs during installation.

Regular maintenance and inspection at least annually by the installer and frequent testing by. Got it, continue to print. A built-in cover tamper switch is activated when the cover is removed.

  MANUAL FORMULAS TECNICAS KURT GIECK PDF

Remove the transmitter’s cover if not already off as described in Mounting Step 1. The should be treated as “RF” i.

The Multi-Point Universal Transmitter may have three contact loops connected to it. Dispose of used batteries promptly. The open slot at the other end of the unit cannot acemco used as a cover pry-off. For this application, the alignment guide strip along one edge of the plate serves no function and may be broken away, if desired.

For UL installations with fire zones, the position 4 ON setting must not be used. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fireaddmco other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result.

Seller does not represent that the product s it sells may not be compromised or circumvented; that the product s will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product s will in all cases provide adequate warning or protection.

To print the manual completely, please, download it. Seller shall have no obligation under this Limited Warranty or otherwise if the product s is altered or improperly repaired or serviced by anyone other than Honeywell factory service.

Risk of fire, explosion, and burns. If concealed wiring is to be used, feed the wires through the concealed wiring entry hole at. Add to my manuals Add.