MANUAL DE GONIOMETRIA PDF

Manual de Goniometria. Cargado por Tamiris de Oliveira . Copyright: © All Rights Reserved. Download as PDF or read online from Scribd. Flag for. Desde seu lançamento, em , o livro Manual de Goniometria, que teve a 2ª Published in: Health & Medicine. 0 Comments; 67 Likes. Title, Manual de goniometria. Authors, Amélia Pasqual Marques, Cristina Marques. Publisher, Manole, ISBN, X, Length ,

Author: Mem Tygonos
Country: Somalia
Language: English (Spanish)
Genre: Sex
Published (Last): 24 June 2009
Pages: 449
PDF File Size: 8.47 Mb
ePub File Size: 4.54 Mb
ISBN: 450-5-49985-333-4
Downloads: 76648
Price: Free* [*Free Regsitration Required]
Uploader: Arashijar

Angle 3 Method 3 Group 1 Mean It is also worth emphasizing that future studies should investigate these findings in the same joints and in other joints of the body in order to confirm the results afforded in the present study. The range of motion evaluation is necessary for the definition both of the propedeutics and of the prognosis in the individual submitted to hand rehabilitation.

While other authors reported that the measurement of ROM can be evaluated both actively and passively, yet passive measurement is used more often as it isolates the structures that can limit motion such as ligaments, joint capsule and antagonistic muscles, thus making it possible to extend the joint to its maximum range of motion, and for this reason, passive measurements are always higher than active. Intraclass correlation coefficient; SD: Neck pain in the general population.

Classification Angle 1 0. Using a standardized evaluation protocol, they concluded that the introduction of the standardized protocol positively influenced the accuracy of the results of the group of surgeons, and stressed the need to use standardization of the goniometry protocol in the evaluation of the ROM to improve the clinicians’ accuracy with the tool and, therefore, to maintain the reliability of its results.

Table 10 Comparison between the methods 1 goniometry2 Corel Draw photogrammetry and 3 ALCimagem photogrammetry in angle 2 flexion of the proximal interphalangeal of the second finger for group 1 scholars. In the comparison between groups for each angle and each method, no significant differences were found between the groups for most of the measurements.

Reliability of fleximetry and goniometry for assessing cervical range of motion among children

Angle 3 Group 3 Method 1 Mean Received Aug 9; Gomiometria Aug Once this procedure was completed the researchers noted down the angles of each examiner on their individual datasheet. Angles analyzed The first measurement in the mold was abduction of the thumb, where the alignment of the goniometer follows steps 1 centralize the goniometer axis on the lateral surface of the radial styloid process, 2 align the proximal arm with the lateral midline of the second metacarpal, using the center goniomerria the second MCP joint as a reference and 3 align the distal arm of the goniometer with the lateral midline of the first metacarpal, using the center of the first MCP joint as a reference.

  ENGINEERING TRIBOLOGY GWIDON W STACHOWIAK PDF

Foram observadas confiabilidades intra-examinador moderado goniometeia excelente para a fleximetria e moderada para a goniometria.

Dessa forma, o examinador 1 realizou a fleximetria e examinador 2 realizou a goniometria. Management of Temporomandibular disorders. As the hand is a structure geared essentially towards function, functional anatomy or kinesiology, or the study of movements, is a vital part of the training of professionals dedicated to the treatment of hand injuries. Reliability is related to the consistency with which the observations can be measured and recorded. Table 4 schematizes the degree of intraexaminer agreement honiometria each group through the intraclass correlation coefficient, observing an excellent level of reliability.

SD – Standard deviation. The volunteers who met the criteria necessary to constitute the sample group of this study were invited to take part in the survey on ,anual absolutely voluntary basis. The active ROM is that performed when the individual uses their own muscles to make the movement, and passive ROM is one in which the examiner applies force to evaluate the range of motion.

Comparison between the methods 1 goniometry2 Corel Draw photogrammetry and 3 ALCimagem photogrammetry in angle 1 palmar abduction of the thumb for group 3 hand therapists.

Mean standard deviation values between the methods for each angle. We also analyzed the interexaminer and intra-instrument reliability for the angular measurements of opening of first web space since the thumb does not favor goniometry use and there is a long list of traumatic or non-traumatic pathologies that decrease the first web spaceflexion of the proximal interphalangeal joint of the forefinger and flexion of the metacarpophalangeal joint of the fifth finger, measurements that were chosen at random.

Goniometrka means that both the group of physiotherapy scholars, and the group of physiotherapists and hand therapists, as they were in full performance of their activities and practicing the method with standardization, presented reliable evaluation means.

D. Joyce White – Google Scholar Citations

Each group evaluated the same plaster-strengthened wax hand mold Figure 1and this was evaluated by all goniomdtria methods and by all the examiners. Many studies verified an increase of interexaminer reliability, when all the examiners used consistent and well defined test positions and measurement methods, which partly corroborates the results found in this study, since they reveal excellent inter ICC 0.

Table 5 Table 5 Mean ICC and standard deviation values for the intraexaminer angular measurements obtained for each angle 1 palmar abduction of thumbed flexion of the proximal interphalangeal joint of the second finger3 flexion of the metacarpophalangeal joint of the fifth finger in each group 1 scholars2 physiotherapists3 hand therapists.

Anamaria Siriani de Oliveira Avenida Bandeirantes, 3. ICC values for the interexaminer angular measurements obtained in the three methods 1 goniometer2 Corel Draw photogrammetry3.

  CATALOGO SELLOS COLOP PDF

Manual de Goniometria

These references were also used by Iunes in in his study that analyzed inter and intraexaminer reliability in postural evaluation using computed photogrammetry.

Thirty volunteer examiners were assessed, hence each one had their ICC and the general was the mean of the ICCs of the examiners. A reliability study of the universal goniometer, fluid goniometer, and electrogoniometer for the measurement of ankle dorsiflexion. The participants were duly briefed on the study goals and signed the informed consent form expressing their agreement to take part in the survey, and received explanations about the procedures that would be required during the study.

Find articles by Claudio Henrique Barbieri. All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License. Angle 2 Group 1 Method 1 Mean The reliability of measurements obtained by an instrument or by an examiner under the same evaluation conditions demonstrates their consistency.

All the examiners evaluated at different times from the others and were only asked to perform the measurement on the dorsum of the hand for standardization of the method, improving accuracy and minimizing the possibility of errors, since many examiners expressed uncertainty regarding the positioning of the goniometer on the hand.

Interrater reliability of the history and physical examination in patients with mechanical neck pain. The results revealed that the groups and the methods proposed presented inter-examiner reliability, generally rated as excellent ICC 0. In a recent bibliographical review, the participants did not find in literature any study with a similar proposal, or with the same division between groups, using a mold as an evaluation instrument and with the same objectives presented.

Table 7 Table 7 Comparison between the methods 1 goniometry2 Corel Draw photogrammetry and 3 ALCimagem photogrammetry in angle 1 palmar abduction of the thumb for group 1 scholars.

Photogrammetry is a more accurate form of static evaluation. Due to the fact that the same mold was used for all the photographs, the tripod height was standardized at 1. The measurements were recorded by the researcher and later compared within each group, between the groups and between instruments.

Table 22 Comparison between the groups 1 scholars2 physiotherapists and 3 hand therapists in angle 3 manua, of the metacarpophalangeal of the fifth finger for method 1 goniometry. There were no markers used. Unravelling the complexity of muscle impairment in chronic neck pain.

These advantages made manual goniometry highly accessible in the physiotherapy clinic.